Hager 4501 SVR FR Exit Device - Fire Rated - 3'0"x 7'0" Door

Price:

1,178.96



Free shipping for all order of $700
Place your order by 2:00 PM EST for same day shipping for all items in stock
Hager 4501 SVR Exit Device - Non Rated - 3'0"x 7'0" Door
Hager 4501 SVR Exit Device - Non Rated - 3'0"x 7'0" Door
1,119.35
1,119.35
Hager 4501 SVR Exit Device - Non Rated - 3'0"x 8'0" Door
Hager 4501 SVR Exit Device - Non Rated - 3'0"x 8'0" Door
1,143.64
1,143.64

Hager 4501 SVR FR Exit Device - Fire Rated - 3'0"x 7'0" Door

https://www.doorwaysplus.com/web/image/product.template/31799/image_1920?unique=d9a10d1
(0 review)

Hager 4501 SVR FR Exit Device - Fire Rated - 3'0"x 7'0" Door
Lead Time(s):
Mechanical Versions: 4-7 Business Days
Electrical Options: 3-4 weeks

1,178.96 1178.96 USD 1,178.96

1,178.96

Not Available For Sale


  • Brand
  • Series
  • Finish with BHMA code
  • Exit Device Type
  • Exit Device Fire Rating
  • Door Opening Width
  • Door Height
  • Hager Exit Device Prefixes

This combination does not exist.


Share :

Hager 4501 SVR FR Exit Device - Fire Rated - 3'0"x 7'0" Door


The Hager 4501 SVR FR is an extra heavy-duty, Fire-Rated Surface Vertical Rod exit device engineered for maximum life safety on double-door applications. Specifically designed for 36" x 84" (3'0" x 7'0") openings, this Grade 1 panic bar provides critical two-point latching (top and bottom) to ensure fire doors remain closed and latched during an emergency. It is the premier choice for fire-rated stairwell doors, mechanical rooms, and high-occupancy corridors in hospitals, schools, and government facilities.

Ultimate Fire Protection and Code Compliance

As a Fire-Rated (FR) hardware solution, the Hager 4501-SVR-FR is UL Listed for Fire Exit Hardware and suitable for use on doors rated up to 3 hours. To maintain the integrity of a fire barrier, this device does not include mechanical dogging, ensuring the door is always "positive-latching." The top features a stainless steel Pullman-type latchbolt, while the bottom bolt secures into a floor strike, providing a robust seal against smoke and flame passage.

Electrified Options & Prefixes

To support advanced facility monitoring and integrated fire alarm systems, the Hager 4501 SVR FR can be equipped with various electrified prefixes:

  • RX - Request to Exit Switch: Monitors the internal switch to signal authorized egress to the control system.
  • RX2 - Dual Request to Exit Switches: Provides two separate monitoring signals for system redundancy.
  • LM - Latchbolt Monitoring: Notifies the security system whenever the rods/latches are retracted or extended.
  • RXLM - Request to Exit and Latchbolt Monitoring: A combined solution for monitoring both occupant exit and latch status.
  • AI - Authorized Ingress: Specifically monitors the exterior trim to track authorized entry attempts.
  • RXAI - Authorized Ingress with Key Monitoring: High-security tracking of both ingress and physical key cylinder usage.
  • DE - Delayed Egress: Delays door opening for 15-30 seconds to prevent unauthorized exiting (requires fire alarm integration).
  • OBDE - Onboard Delayed Egress: A self-contained, all-in-one delayed egress system for fire-rated openings.
  • MLR - Motorized Latch Retraction: Allows for remote electric unlocking; ideal for use with automatic door operators.
  • MLRX - Motorized Latch Retraction w/ Request to Exit: Latch retraction combined with egress monitoring.
  • MLRXLM - MLR w/ Request to Exit & Latchbolt Monitoring: The complete suite for high-level security and automation.
  • MLRLM - Motorized Latch Retraction w/ Latchbolt Monitoring: Combines motorized control with real-time latch position status.

Technical Specifications

FeatureSpecification
SeriesHager 4500 Series
Device TypeSurface Vertical Rod (SVR)
RatingUL Fire-Rated (UL10C)
GradeANSI/BHMA A156.3 Grade 1
Door Size3'0" x 7'0" (36" x 84")
Top LatchStainless Steel Pullman Type
DoggingNone (Required for Fire-Rated Hardware)
Fire RatingUp to 3 Hours (UL/cUL Listed)
HandingNon-Handed (Fully Reversible)
FastenersIncludes Thru Bolts as standard for fire doors

Standards & Institutional Performance

  • Fire Safety: UL Listed for Fire Exit Hardware; compliant with NFPA 80 and NFPA 101.
  • Accessibility: Meets ADA requirements for push-force and ease of operation.
  • Durability: Tested to exceed over one million cycles in high-abuse commercial environments.
  • Vandal Resistance: Standard thru-bolt installation ensures the device remains securely attached to the door leaf, preventing rod misalignment and resisting tampering under physical stress.

Finish with BHMA code 626 - US26D Satin Chrome or 630 - US32D Satin Stainless or 613 - US10B Oil Rubbed Bronze or 605 - US3 Polish Brass or 606 - US4 Satin Brass or 625 - US26 Polish Chrome
Hager Exit Device Prefixes RX - Request to Exit Switch or RX2 - Dual Request to Exit Switches or LM - Latchbolt Monitoring or RXLM - Request to Exit and Latchbolt Monitoring or AI - Authorized Ingress or RXAI - Authorized Ingress with Key Monitoring or DE - Delayed Egress or OBDE - Onboard Delayed Egress or MLR - Motorized Latch Retraction or MLRX - Motorized Latch Retraction w/ Request to Exit Switch or MLRXLM - Motorized Latch Retraction w/ Request to Exit Switch & Latchbolt Monitoring or MLRLM - Motorized Latch Retraction w/ Latchbolt Monitoring
Brand Hager
Series Hager - 4500 Series
Exit Device Type SVR Exit Device
Exit Device Fire Rating Fire Rated Door
Door Opening Width 36 Inches
Door Height 7'0" Dr Ht
4500 SVR Chassis Template - T-ED00044-Rev03.pdf
Download
4500 SVR Door Prep Template - T-ED00873-Rev02.pdf
Download
4500 Series SVR Latch Template - T-ED00045-Rev05.pdf
Download
4501 Series SVR Installation Instructions - I-ED00792.pdf
Download
Catalog_2024_ExitsDevices_v00.pdf
Download
Similar Products
Accessory Products

Recently Viewed Items

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.